Electrode pick-up method |
Vacuum pads |
Maximum size of electrode (mm) |
300 × 300 |
Counter electrode aligning method |
Pre-determind position on the photo electrode |
Positioning accuracy ( μm) |
±5 |
Supported photo electrode sizes (mm) |
300 sq, 150 sq, 100 sq, 50 sq, 25 sq (custom sizes are possible if requested) |
Supported counter electrode sizes (mm)
(Interchangeable pick-up heads are available for different size counter electrodes. Machine will ship with a pre requested size pick-up head. Optional pick-up heads for different size electrodes should be ordered separately.
Machine will automatically identify the pick-up head size and switch to appropriate program. ) |
300 × 300, 300 × 150
200 × 200, 200 × 100
150 × 150, 150 × 75
100 × 100, 100 × 50
50 × 50, 25 × 25
(custom sizes are possible if requested)
|
Supported piled-up patterns |
(custom patterns are possible if requested) |
Supported electrode thicknesses (mm) |
0.5 – 5 |
Control method |
Through the control keypad (Programs are stored in the robot’s flash memory) |
PC interface (for programming) |
USB / RS-232 |
Required external items |
Single or double stage rotary oil vacuum pump |
Robot’s maximum moving range (mm) |
400 (X, Y) 55 (Z) |
Power Supply |
100-240 V AC, 50/60 Hz |
Dimensions (W × D × H) (mm) |
500 × 710 × 568 |
Weight |
30 kg |